| Package | Description |
|---|---|
| org.yamcs.protobuf |
| Modifier and Type | Method and Description |
|---|---|
Cop1Status.Builder |
Cop1Status.Builder.addRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field,
Object value) |
Cop1Status.Builder |
Cop1Status.Builder.clear() |
Cop1Status.Builder |
Cop1Status.Builder.clearClcw()
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
Cop1Status.Builder |
Cop1Status.Builder.clearCop1Active()
if false, all frames are immediately transmitted (i.e.
|
Cop1Status.Builder |
Cop1Status.Builder.clearField(com.google.protobuf.Descriptors.FieldDescriptor field) |
Cop1Status.Builder |
Cop1Status.Builder.clearNnR()
the nR from the previous CLCW
optional uint32 nnR = 6; |
Cop1Status.Builder |
Cop1Status.Builder.clearOneof(com.google.protobuf.Descriptors.OneofDescriptor oneof) |
Cop1Status.Builder |
Cop1Status.Builder.clearOutQueueNumFrames()
number of frames in the out queue (waiting to be picked up by the master chain multiplexer)
optional uint32 outQueueNumFrames = 9; |
Cop1Status.Builder |
Cop1Status.Builder.clearSentQueueNumFrames()
number of unacknowledged frames in the sent queue
optional uint32 sentQueueNumFrames = 8; |
Cop1Status.Builder |
Cop1Status.Builder.clearSetBypassAll()
relevant if cop1Active = false -> set the bypass flag on all outgoing frames
optional bool setBypassAll = 2; |
Cop1Status.Builder |
Cop1Status.Builder.clearState()
current state of FOP1 state machine, only relevant if cop1Active = true
optional .yamcs.protobuf.cop1.Cop1State state = 4; |
Cop1Status.Builder |
Cop1Status.Builder.clearTxCount()
how many times the last frame has been transmitted
optional uint32 txCount = 10; |
Cop1Status.Builder |
Cop1Status.Builder.clearVS()
V(S) - Transmitter Frame Sequence Number;
optional uint32 vS = 5; |
Cop1Status.Builder |
Cop1Status.Builder.clearWaitQueueNumTC()
number of TC packets in the wait queue
optional uint32 waitQueueNumTC = 7; |
Cop1Status.Builder |
Cop1Status.Builder.clone() |
Cop1Status.Builder |
Cop1Status.Builder.mergeClcw(Clcw value)
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
Cop1Status.Builder |
Cop1Status.Builder.mergeFrom(com.google.protobuf.CodedInputStream input,
com.google.protobuf.ExtensionRegistryLite extensionRegistry) |
Cop1Status.Builder |
Cop1Status.Builder.mergeFrom(Cop1Status other) |
Cop1Status.Builder |
Cop1Status.Builder.mergeFrom(com.google.protobuf.Message other) |
Cop1Status.Builder |
Cop1Status.Builder.mergeUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields) |
static Cop1Status.Builder |
Cop1Status.newBuilder() |
static Cop1Status.Builder |
Cop1Status.newBuilder(Cop1Status prototype) |
Cop1Status.Builder |
Cop1Status.newBuilderForType() |
protected Cop1Status.Builder |
Cop1Status.newBuilderForType(com.google.protobuf.GeneratedMessageV3.BuilderParent parent) |
Cop1Status.Builder |
Cop1Status.Builder.setClcw(Clcw.Builder builderForValue)
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
Cop1Status.Builder |
Cop1Status.Builder.setClcw(Clcw value)
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
Cop1Status.Builder |
Cop1Status.Builder.setCop1Active(boolean value)
if false, all frames are immediately transmitted (i.e.
|
Cop1Status.Builder |
Cop1Status.Builder.setField(com.google.protobuf.Descriptors.FieldDescriptor field,
Object value) |
Cop1Status.Builder |
Cop1Status.Builder.setNnR(int value)
the nR from the previous CLCW
optional uint32 nnR = 6; |
Cop1Status.Builder |
Cop1Status.Builder.setOutQueueNumFrames(int value)
number of frames in the out queue (waiting to be picked up by the master chain multiplexer)
optional uint32 outQueueNumFrames = 9; |
Cop1Status.Builder |
Cop1Status.Builder.setRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field,
int index,
Object value) |
Cop1Status.Builder |
Cop1Status.Builder.setSentQueueNumFrames(int value)
number of unacknowledged frames in the sent queue
optional uint32 sentQueueNumFrames = 8; |
Cop1Status.Builder |
Cop1Status.Builder.setSetBypassAll(boolean value)
relevant if cop1Active = false -> set the bypass flag on all outgoing frames
optional bool setBypassAll = 2; |
Cop1Status.Builder |
Cop1Status.Builder.setState(Cop1State value)
current state of FOP1 state machine, only relevant if cop1Active = true
optional .yamcs.protobuf.cop1.Cop1State state = 4; |
Cop1Status.Builder |
Cop1Status.Builder.setTxCount(int value)
how many times the last frame has been transmitted
optional uint32 txCount = 10; |
Cop1Status.Builder |
Cop1Status.Builder.setUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields) |
Cop1Status.Builder |
Cop1Status.Builder.setVS(int value)
V(S) - Transmitter Frame Sequence Number;
optional uint32 vS = 5; |
Cop1Status.Builder |
Cop1Status.Builder.setWaitQueueNumTC(int value)
number of TC packets in the wait queue
optional uint32 waitQueueNumTC = 7; |
Cop1Status.Builder |
Cop1Status.toBuilder() |
Copyright © 2019 Space Applications Services. All rights reserved.