public static final class Cop1Status.Builder extends com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder> implements Cop1StatusOrBuilder
this message will be sent periodically via the websocketProtobuf type
yamcs.protobuf.cop1.Cop1Status| Modifier and Type | Method and Description |
|---|---|
Cop1Status.Builder |
addRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field,
Object value) |
Cop1Status |
build() |
Cop1Status |
buildPartial() |
Cop1Status.Builder |
clear() |
Cop1Status.Builder |
clearClcw()
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
Cop1Status.Builder |
clearCop1Active()
if false, all frames are immediately transmitted (i.e.
|
Cop1Status.Builder |
clearField(com.google.protobuf.Descriptors.FieldDescriptor field) |
Cop1Status.Builder |
clearName()
link name for which this status applies
it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11; |
Cop1Status.Builder |
clearNnR()
the nR from the previous CLCW
optional uint32 nnR = 6; |
Cop1Status.Builder |
clearOneof(com.google.protobuf.Descriptors.OneofDescriptor oneof) |
Cop1Status.Builder |
clearOutQueueNumFrames()
number of frames in the out queue (waiting to be picked up by the master chain multiplexer)
optional uint32 outQueueNumFrames = 9; |
Cop1Status.Builder |
clearSentQueueNumFrames()
number of unacknowledged frames in the sent queue
optional uint32 sentQueueNumFrames = 8; |
Cop1Status.Builder |
clearSetBypassAll()
relevant if cop1Active = false -> set the bypass flag on all outgoing frames
optional bool setBypassAll = 2; |
Cop1Status.Builder |
clearState()
current state of FOP1 state machine, only relevant if cop1Active = true
optional .yamcs.protobuf.cop1.Cop1State state = 4; |
Cop1Status.Builder |
clearTxCount()
how many times the last frame has been transmitted
optional uint32 txCount = 10; |
Cop1Status.Builder |
clearVS()
V(S) - Transmitter Frame Sequence Number;
optional uint32 vS = 5; |
Cop1Status.Builder |
clearWaitQueueNumTC()
number of TC packets in the wait queue
optional uint32 waitQueueNumTC = 7; |
Cop1Status.Builder |
clone() |
Clcw |
getClcw()
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
Clcw.Builder |
getClcwBuilder()
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
ClcwOrBuilder |
getClcwOrBuilder()
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
boolean |
getCop1Active()
if false, all frames are immediately transmitted (i.e.
|
Cop1Status |
getDefaultInstanceForType() |
static com.google.protobuf.Descriptors.Descriptor |
getDescriptor() |
com.google.protobuf.Descriptors.Descriptor |
getDescriptorForType() |
String |
getName()
link name for which this status applies
it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11; |
com.google.protobuf.ByteString |
getNameBytes()
link name for which this status applies
it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11; |
int |
getNnR()
the nR from the previous CLCW
optional uint32 nnR = 6; |
int |
getOutQueueNumFrames()
number of frames in the out queue (waiting to be picked up by the master chain multiplexer)
optional uint32 outQueueNumFrames = 9; |
int |
getSentQueueNumFrames()
number of unacknowledged frames in the sent queue
optional uint32 sentQueueNumFrames = 8; |
boolean |
getSetBypassAll()
relevant if cop1Active = false -> set the bypass flag on all outgoing frames
optional bool setBypassAll = 2; |
Cop1State |
getState()
current state of FOP1 state machine, only relevant if cop1Active = true
optional .yamcs.protobuf.cop1.Cop1State state = 4; |
int |
getTxCount()
how many times the last frame has been transmitted
optional uint32 txCount = 10; |
int |
getVS()
V(S) - Transmitter Frame Sequence Number;
optional uint32 vS = 5; |
int |
getWaitQueueNumTC()
number of TC packets in the wait queue
optional uint32 waitQueueNumTC = 7; |
boolean |
hasClcw()
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
boolean |
hasCop1Active()
if false, all frames are immediately transmitted (i.e.
|
boolean |
hasName()
link name for which this status applies
it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11; |
boolean |
hasNnR()
the nR from the previous CLCW
optional uint32 nnR = 6; |
boolean |
hasOutQueueNumFrames()
number of frames in the out queue (waiting to be picked up by the master chain multiplexer)
optional uint32 outQueueNumFrames = 9; |
boolean |
hasSentQueueNumFrames()
number of unacknowledged frames in the sent queue
optional uint32 sentQueueNumFrames = 8; |
boolean |
hasSetBypassAll()
relevant if cop1Active = false -> set the bypass flag on all outgoing frames
optional bool setBypassAll = 2; |
boolean |
hasState()
current state of FOP1 state machine, only relevant if cop1Active = true
optional .yamcs.protobuf.cop1.Cop1State state = 4; |
boolean |
hasTxCount()
how many times the last frame has been transmitted
optional uint32 txCount = 10; |
boolean |
hasVS()
V(S) - Transmitter Frame Sequence Number;
optional uint32 vS = 5; |
boolean |
hasWaitQueueNumTC()
number of TC packets in the wait queue
optional uint32 waitQueueNumTC = 7; |
protected com.google.protobuf.GeneratedMessageV3.FieldAccessorTable |
internalGetFieldAccessorTable() |
boolean |
isInitialized() |
Cop1Status.Builder |
mergeClcw(Clcw value)
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
Cop1Status.Builder |
mergeFrom(com.google.protobuf.CodedInputStream input,
com.google.protobuf.ExtensionRegistryLite extensionRegistry) |
Cop1Status.Builder |
mergeFrom(Cop1Status other) |
Cop1Status.Builder |
mergeFrom(com.google.protobuf.Message other) |
Cop1Status.Builder |
mergeUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields) |
Cop1Status.Builder |
setClcw(Clcw.Builder builderForValue)
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
Cop1Status.Builder |
setClcw(Clcw value)
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3; |
Cop1Status.Builder |
setCop1Active(boolean value)
if false, all frames are immediately transmitted (i.e.
|
Cop1Status.Builder |
setField(com.google.protobuf.Descriptors.FieldDescriptor field,
Object value) |
Cop1Status.Builder |
setName(String value)
link name for which this status applies
it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11; |
Cop1Status.Builder |
setNameBytes(com.google.protobuf.ByteString value)
link name for which this status applies
it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11; |
Cop1Status.Builder |
setNnR(int value)
the nR from the previous CLCW
optional uint32 nnR = 6; |
Cop1Status.Builder |
setOutQueueNumFrames(int value)
number of frames in the out queue (waiting to be picked up by the master chain multiplexer)
optional uint32 outQueueNumFrames = 9; |
Cop1Status.Builder |
setRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field,
int index,
Object value) |
Cop1Status.Builder |
setSentQueueNumFrames(int value)
number of unacknowledged frames in the sent queue
optional uint32 sentQueueNumFrames = 8; |
Cop1Status.Builder |
setSetBypassAll(boolean value)
relevant if cop1Active = false -> set the bypass flag on all outgoing frames
optional bool setBypassAll = 2; |
Cop1Status.Builder |
setState(Cop1State value)
current state of FOP1 state machine, only relevant if cop1Active = true
optional .yamcs.protobuf.cop1.Cop1State state = 4; |
Cop1Status.Builder |
setTxCount(int value)
how many times the last frame has been transmitted
optional uint32 txCount = 10; |
Cop1Status.Builder |
setUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields) |
Cop1Status.Builder |
setVS(int value)
V(S) - Transmitter Frame Sequence Number;
optional uint32 vS = 5; |
Cop1Status.Builder |
setWaitQueueNumTC(int value)
number of TC packets in the wait queue
optional uint32 waitQueueNumTC = 7; |
getAllFields, getField, getFieldBuilder, getOneofFieldDescriptor, getParentForChildren, getRepeatedField, getRepeatedFieldBuilder, getRepeatedFieldCount, getUnknownFields, hasField, hasOneof, internalGetMapField, internalGetMutableMapField, isClean, markClean, newBuilderForField, onBuilt, onChanged, setUnknownFieldsProto3findInitializationErrors, getInitializationErrorString, internalMergeFrom, mergeDelimitedFrom, mergeDelimitedFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, newUninitializedMessageException, toStringaddAll, addAll, mergeFrom, newUninitializedMessageExceptionequals, finalize, getClass, hashCode, notify, notifyAll, wait, wait, waitpublic static final com.google.protobuf.Descriptors.Descriptor getDescriptor()
protected com.google.protobuf.GeneratedMessageV3.FieldAccessorTable internalGetFieldAccessorTable()
internalGetFieldAccessorTable in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>public Cop1Status.Builder clear()
clear in interface com.google.protobuf.Message.Builderclear in interface com.google.protobuf.MessageLite.Builderclear in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>public com.google.protobuf.Descriptors.Descriptor getDescriptorForType()
getDescriptorForType in interface com.google.protobuf.Message.BuildergetDescriptorForType in interface com.google.protobuf.MessageOrBuildergetDescriptorForType in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>public Cop1Status getDefaultInstanceForType()
getDefaultInstanceForType in interface com.google.protobuf.MessageLiteOrBuildergetDefaultInstanceForType in interface com.google.protobuf.MessageOrBuilderpublic Cop1Status build()
build in interface com.google.protobuf.Message.Builderbuild in interface com.google.protobuf.MessageLite.Builderpublic Cop1Status buildPartial()
buildPartial in interface com.google.protobuf.Message.BuilderbuildPartial in interface com.google.protobuf.MessageLite.Builderpublic Cop1Status.Builder clone()
clone in interface com.google.protobuf.Message.Builderclone in interface com.google.protobuf.MessageLite.Builderclone in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>public Cop1Status.Builder setField(com.google.protobuf.Descriptors.FieldDescriptor field, Object value)
setField in interface com.google.protobuf.Message.BuildersetField in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>public Cop1Status.Builder clearField(com.google.protobuf.Descriptors.FieldDescriptor field)
clearField in interface com.google.protobuf.Message.BuilderclearField in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>public Cop1Status.Builder clearOneof(com.google.protobuf.Descriptors.OneofDescriptor oneof)
clearOneof in interface com.google.protobuf.Message.BuilderclearOneof in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>public Cop1Status.Builder setRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field, int index, Object value)
setRepeatedField in interface com.google.protobuf.Message.BuildersetRepeatedField in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>public Cop1Status.Builder addRepeatedField(com.google.protobuf.Descriptors.FieldDescriptor field, Object value)
addRepeatedField in interface com.google.protobuf.Message.BuilderaddRepeatedField in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>public Cop1Status.Builder mergeFrom(com.google.protobuf.Message other)
mergeFrom in interface com.google.protobuf.Message.BuildermergeFrom in class com.google.protobuf.AbstractMessage.Builder<Cop1Status.Builder>public Cop1Status.Builder mergeFrom(Cop1Status other)
public final boolean isInitialized()
isInitialized in interface com.google.protobuf.MessageLiteOrBuilderisInitialized in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>public Cop1Status.Builder mergeFrom(com.google.protobuf.CodedInputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws IOException
mergeFrom in interface com.google.protobuf.Message.BuildermergeFrom in interface com.google.protobuf.MessageLite.BuildermergeFrom in class com.google.protobuf.AbstractMessage.Builder<Cop1Status.Builder>IOExceptionpublic boolean hasName()
link name for which this status applies it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11;hasName in interface Cop1StatusOrBuilderpublic String getName()
link name for which this status applies it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11;getName in interface Cop1StatusOrBuilderpublic com.google.protobuf.ByteString getNameBytes()
link name for which this status applies it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11;getNameBytes in interface Cop1StatusOrBuilderpublic Cop1Status.Builder setName(String value)
link name for which this status applies it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11;public Cop1Status.Builder clearName()
link name for which this status applies it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11;public Cop1Status.Builder setNameBytes(com.google.protobuf.ByteString value)
link name for which this status applies it is present when this message is sent over the websocket as there might be multiple COP1 links subscribed
optional string name = 11;public boolean hasCop1Active()
if false, all frames are immediately transmitted (i.e. COP1 is disabled)
optional bool cop1Active = 1;hasCop1Active in interface Cop1StatusOrBuilderpublic boolean getCop1Active()
if false, all frames are immediately transmitted (i.e. COP1 is disabled)
optional bool cop1Active = 1;getCop1Active in interface Cop1StatusOrBuilderpublic Cop1Status.Builder setCop1Active(boolean value)
if false, all frames are immediately transmitted (i.e. COP1 is disabled)
optional bool cop1Active = 1;public Cop1Status.Builder clearCop1Active()
if false, all frames are immediately transmitted (i.e. COP1 is disabled)
optional bool cop1Active = 1;public boolean hasSetBypassAll()
relevant if cop1Active = false -> set the bypass flag on all outgoing frames
optional bool setBypassAll = 2;hasSetBypassAll in interface Cop1StatusOrBuilderpublic boolean getSetBypassAll()
relevant if cop1Active = false -> set the bypass flag on all outgoing frames
optional bool setBypassAll = 2;getSetBypassAll in interface Cop1StatusOrBuilderpublic Cop1Status.Builder setSetBypassAll(boolean value)
relevant if cop1Active = false -> set the bypass flag on all outgoing frames
optional bool setBypassAll = 2;public Cop1Status.Builder clearSetBypassAll()
relevant if cop1Active = false -> set the bypass flag on all outgoing frames
optional bool setBypassAll = 2;public boolean hasClcw()
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3;hasClcw in interface Cop1StatusOrBuilderpublic Clcw getClcw()
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3;getClcw in interface Cop1StatusOrBuilderpublic Cop1Status.Builder setClcw(Clcw value)
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3;public Cop1Status.Builder setClcw(Clcw.Builder builderForValue)
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3;public Cop1Status.Builder mergeClcw(Clcw value)
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3;public Cop1Status.Builder clearClcw()
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3;public Clcw.Builder getClcwBuilder()
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3;public ClcwOrBuilder getClcwOrBuilder()
last received CLCW
optional .yamcs.protobuf.cop1.Clcw clcw = 3;getClcwOrBuilder in interface Cop1StatusOrBuilderpublic boolean hasState()
current state of FOP1 state machine, only relevant if cop1Active = true
optional .yamcs.protobuf.cop1.Cop1State state = 4;hasState in interface Cop1StatusOrBuilderpublic Cop1State getState()
current state of FOP1 state machine, only relevant if cop1Active = true
optional .yamcs.protobuf.cop1.Cop1State state = 4;getState in interface Cop1StatusOrBuilderpublic Cop1Status.Builder setState(Cop1State value)
current state of FOP1 state machine, only relevant if cop1Active = true
optional .yamcs.protobuf.cop1.Cop1State state = 4;public Cop1Status.Builder clearState()
current state of FOP1 state machine, only relevant if cop1Active = true
optional .yamcs.protobuf.cop1.Cop1State state = 4;public boolean hasVS()
V(S) - Transmitter Frame Sequence Number;
optional uint32 vS = 5;hasVS in interface Cop1StatusOrBuilderpublic int getVS()
V(S) - Transmitter Frame Sequence Number;
optional uint32 vS = 5;getVS in interface Cop1StatusOrBuilderpublic Cop1Status.Builder setVS(int value)
V(S) - Transmitter Frame Sequence Number;
optional uint32 vS = 5;public Cop1Status.Builder clearVS()
V(S) - Transmitter Frame Sequence Number;
optional uint32 vS = 5;public boolean hasNnR()
the nR from the previous CLCW
optional uint32 nnR = 6;hasNnR in interface Cop1StatusOrBuilderpublic int getNnR()
the nR from the previous CLCW
optional uint32 nnR = 6;getNnR in interface Cop1StatusOrBuilderpublic Cop1Status.Builder setNnR(int value)
the nR from the previous CLCW
optional uint32 nnR = 6;public Cop1Status.Builder clearNnR()
the nR from the previous CLCW
optional uint32 nnR = 6;public boolean hasWaitQueueNumTC()
number of TC packets in the wait queue
optional uint32 waitQueueNumTC = 7;hasWaitQueueNumTC in interface Cop1StatusOrBuilderpublic int getWaitQueueNumTC()
number of TC packets in the wait queue
optional uint32 waitQueueNumTC = 7;getWaitQueueNumTC in interface Cop1StatusOrBuilderpublic Cop1Status.Builder setWaitQueueNumTC(int value)
number of TC packets in the wait queue
optional uint32 waitQueueNumTC = 7;public Cop1Status.Builder clearWaitQueueNumTC()
number of TC packets in the wait queue
optional uint32 waitQueueNumTC = 7;public boolean hasSentQueueNumFrames()
number of unacknowledged frames in the sent queue
optional uint32 sentQueueNumFrames = 8;hasSentQueueNumFrames in interface Cop1StatusOrBuilderpublic int getSentQueueNumFrames()
number of unacknowledged frames in the sent queue
optional uint32 sentQueueNumFrames = 8;getSentQueueNumFrames in interface Cop1StatusOrBuilderpublic Cop1Status.Builder setSentQueueNumFrames(int value)
number of unacknowledged frames in the sent queue
optional uint32 sentQueueNumFrames = 8;public Cop1Status.Builder clearSentQueueNumFrames()
number of unacknowledged frames in the sent queue
optional uint32 sentQueueNumFrames = 8;public boolean hasOutQueueNumFrames()
number of frames in the out queue (waiting to be picked up by the master chain multiplexer)
optional uint32 outQueueNumFrames = 9;hasOutQueueNumFrames in interface Cop1StatusOrBuilderpublic int getOutQueueNumFrames()
number of frames in the out queue (waiting to be picked up by the master chain multiplexer)
optional uint32 outQueueNumFrames = 9;getOutQueueNumFrames in interface Cop1StatusOrBuilderpublic Cop1Status.Builder setOutQueueNumFrames(int value)
number of frames in the out queue (waiting to be picked up by the master chain multiplexer)
optional uint32 outQueueNumFrames = 9;public Cop1Status.Builder clearOutQueueNumFrames()
number of frames in the out queue (waiting to be picked up by the master chain multiplexer)
optional uint32 outQueueNumFrames = 9;public boolean hasTxCount()
how many times the last frame has been transmitted
optional uint32 txCount = 10;hasTxCount in interface Cop1StatusOrBuilderpublic int getTxCount()
how many times the last frame has been transmitted
optional uint32 txCount = 10;getTxCount in interface Cop1StatusOrBuilderpublic Cop1Status.Builder setTxCount(int value)
how many times the last frame has been transmitted
optional uint32 txCount = 10;public Cop1Status.Builder clearTxCount()
how many times the last frame has been transmitted
optional uint32 txCount = 10;public final Cop1Status.Builder setUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields)
setUnknownFields in interface com.google.protobuf.Message.BuildersetUnknownFields in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>public final Cop1Status.Builder mergeUnknownFields(com.google.protobuf.UnknownFieldSet unknownFields)
mergeUnknownFields in interface com.google.protobuf.Message.BuildermergeUnknownFields in class com.google.protobuf.GeneratedMessageV3.Builder<Cop1Status.Builder>Copyright © 2020 Space Applications Services. All rights reserved.